E Series Source Meter
The E series high-voltage source meter support up to 3500V and weak current signal 1nA.
In the first working quadrant, the output and measurement voltage is 0~3500V, the output and measurement current is 0~100mA. It supports constant voltage and constant current working mode, and supports I-V scanning mode
It can be used in IGBT breakdown voltage test, IGBT dynamic test, bus capacitance charging power supply, IGBT burn-in power supply, lightning protection diode withstand voltage test, varistor withstand voltage test, and so on.
其恆流模式有利於快速測量擊穿點。
E Series Specification Brief
| Model | Max. Current | Max. Voltage | Max. Output Power |
|---|---|---|---|
| E100 | 100mA | 1200V | 120W |
| E200 | 100mA | 2200V | 220W |
| E300 | 100mA | 3500V | 350W |
Basic Specification
| Item | Specification |
|---|---|
| Max. Output Power | 350W,3500V/100mA (based on different model) |
| Voltage Output Time | < 5ms |
| Output Interface | E100:Triaxial BNC E200、E300:Triaxial KHV |
| Protection Function | Supports emergency stop and high-voltage interlock protection |
| Interface | RS232、Ethernet |
| Trigger | Support for trig in and trig out |
| Dimension (L*W*H) | 19-inch 2U chassis, depth: 520mm (Excluding mounting unit and emergency stop button) |
Voltage
| Measuring Range | Resolution | Accuracy |
|---|---|---|
| 100V | 10mV | ±0.1%±40mV |
| 600V | 60mV | ±0.1%±100mV |
| 1200V | 120mV | ±0.1%±300mV |
| 1600V | 160mV | ±0.1%±400mV |
| 2200V | 220mV | ±0.1%±700mV |
| 3500V | 350mV | ±0.1%±900mV |
Current
| Measuring Range | Resolution | Accuracy |
|---|---|---|
| 1μA | 100pA | ±0.1%±1nA |
| 10μA | 1nA | ±0.1%±5nA |
| 100μA | 10nA | ±0.1%±50nA |
| 1mA | 100nA | ±0.1%±300nA |
| 10mA | 1μA | ±0.1%±5μA |
| 100mA | 10μA | ±0.1%±10μA |